T80HV TurboCharger
TM
SPECIFICATIONS
Maximum output current ……...... 80 Amps continuous at up to 45
o
C/113
o
F ambient temperature
Battery voltages …………………. 12, 24, 36, or 48 VDC nominal
Max PV input current ……………. 70 Amps
Maximum PV input voltage (Voc) … 180VDC Maximum Open Circuit Voltage (Voc), 160VDC Max Operating (Vmp)
Minimum PV input voltage (Vmp) ... PV Vmp must be at least 16% greater than the highest battery charge voltage set point.
For 12 volt batteries this is typically 18.56VDC, for 24v batteries typically 37.12VDC,
and for 48v batteries it is typically 74.24VDC. The input voltage is measured at the input
of the T80 after the wiring and the PV array temperature must be considered with Vmp.
Max PV array power …………….. 5120 Watts (maximum when equalizing a 48v battery to 64v at 80 Amps)
2560 Watts for equalizing a 24 volt battery and 1280 watts for eq a 12 volt battery
Charge regulation modes ….….… Bulk, Absorption, Float, Standby, Auto Equalization, and Manual Equalization
MPPT Features ……………….….. Apollo Solar patent-pending MPPT algorithm harvests the optimum power
under all conditions of clouds or temperature.
Battery temperature compensation... 6.0mV per
o
C per 2 volt cell
Display ………………………….… Built-in 4-line 20-character LCD with back light
Status reporting ………………..… LCD status screen displays Input voltage and current, Output voltage and
current, Charge-mode, and Battery State-Of-Charge (SOC).
Data logging ……………….…….. Logs energy harvested for 90 days. LCD displays Watt-hours, kW-hours,
Amp hours, and hours each day that Float mode is active.
Energy Monitor ……………….….. LCD shows SOC (State-of-Charge) in a fuel gauge style bar graph as
well as % Full, Amp-hours, Watt-hrs and present charge or discharge current.
A 50mV/500Amp shunt is required to use the Energy Monitor features.
Auxiliary relays ……………….….. Two independent relays with form A (SPST) contacts for control of external
devices. Configurable as NO or NC. Contact rating ½ Amp, 50 VDC.
Operating Temperature ………….. -40
o
C to +60
o
C, Full power output to +45
o
C ambient, Output current automatically
and de-rating ramped down above 45
o
C: 1Amp per 1
o
C increase in temperature and then softly restored
as temperature decreases.
Standby Power ……………………. Less than 2 Watts
Data Communication Options …… Card slot for optional Apollo Network and link to Remote Display and Internet Gateway.
Connectors ………………………… Power lugs accept 14 to 1/0. No. 2 wire recommended.
Conduit knockouts ………….….… One 1” or 1-¼” and one ½” or ¾” on left side. Two ½” or ¾” on back.
Two 1” or 1-¼” on bottom. Bottom holes line up with power connectors.
Unit dimensions ……………….…. 38.7cm X 21.6cm X 11.1cm (15.2“ X 8.5“ X 4.4“) Length X Width X Depth
Shipping dimensions ……….…… 53cm X 31.8cm X 21.6cm (21“ X 12 ½“ X 8 ½“)
Weight …………………….………. Unit: 7.3 kg/16 lbs Shipping weight: 10 kg/22 lbs
Certification ………………….….… UL1741, CSA C22.2 No. 107.1
Warranty ……………………………. 5-year Limited Warranty
Environmental rating …………..… Ambient Temperature: –40°C to +60°C; Storage Temperature: –55°C to +100°C;
Humidity: 100% non-condensing; Enclosure: Indoor Type 1
Included Accessory Kit …………… Apollo Shunt Board and cable, battery monitor cable, and Battery Temp Sensor
Optional Accessories …………….. True Sine Wave, Split-Phase Inverter/Chargers TSW3224, TSW4048;
Inverter Switchgear Module (ISM) enclosure with DC and AC breakers, Pre-Wired Panels
(PWP) which included a T80 or T80HV, TSW and ISM factory wired and tested,
Communications Gateway with optional GSM modem for Remote Monitoring
via local ethernet or via Internet
23 Francis J. Clarke Circle
Bethel, CT 06801
(203) 790-6400
www.ApolloSolar.com
Specifications are subject to change without notice. April 2012